OnyxClientSetup supports silent mode using the following command line parameters:
Parameter | Value | Description |
---|---|---|
-? | Help desk for command line parameters | |
-Auto | Installation starts automatically | |
-Lang= | Language Number | For client language use: 1=DE, 2=EN, 3=RU, 4=ES, 5=IT, 6=FR, 7=CZ, 8=HU |
-Server= | Server Name | z.B.: [MYSERVER]@MYSERVER oder [MYSERVER]@172.192.1.250 |
-PORT= | IP-Port number | Optional; Default IP-Port nubmer=16300 |
-PATH= | Install Folder | Local install folder or Default |
- If any of the parameters is missing, OnyxClientSetup will stop at this point
- For -PATH=Default folder ..\Programs\Image Instruments\Onyx3Client\ is used
- If not specified, subfolder Onyx3Client will be created automatically
- In case of empty spaces in folder name, use quotation marks: -PATH=“C:\\Onyx 3Ceph“
Example
The command line below connects to the server via port 16300 and installs a client with GERMAN langage settings in the standard installation folder:
OnyxClientSetup.exe -Auto -Server=[SRV]@SRV -Lang=1 -Path=Default
The command line below connects to the server via port 16500 and installs a client with ENGLISH langage settings in folder D:\OnyxCeph\Onyx3Client:
OnyxClientSetup.exe -Auto -Server=[SRV]@172.1.1.250 -Port=16500 -Lang=2 -Path=D:\OnyxCeph