As of update >3.2.157, module Segmentation is delivered in a revised version. This affects the following features, among others:
Since the Separate substep no longer allowed any intervention options in the previous workflow, it no longer has to be called up manually in the new user interface using a separate key, but is now part of the Complete substep.
Previously, it was not possible to modify the segmentation after applying steps Separation and Completion. The new concept now allows an unrestricted change between segmenting and completing, even if the completed data record has already been saved as a finding and opened again in the module. A new completion only takes place for the corrected crowns.
By optimizing the parallel processing of the crown for completing algorithm, the substep was accelerated significantly.
A manual correction of the template tooth fit is now possible by manually adjusting the points M (mesial curve oct), D (distal curve point) and A (apex point) using Drag&Drop. The re-adjustment is performed immediately after moving one of these points - so there is no need to open and exit a separate correction mode anymore.
The calculation of crown contacts has been modified and should now be faster and more accurate.
If the findings to be segmented include superimposed volume data in addition to the surface scan, an attempt can be made to individualize the root geometry for the completed tooth using the volume data via the tooth list context menu item [Volume data].
In order to visually store certain tooth features (e.g. implant, denture) for the further processing sequence, segmented crowns can now be assigned 2 different alternative colors on the outside white.\