en:waefer_creation_3d
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionLast revisionBoth sides next revision | ||
en:waefer_creation_3d [2019/08/20 17:43] – [Module user interface] onyxadmin | en:waefer_creation_3d [2024/03/02 15:29] – [Module Waefer Creation 3D] onyxadmin | ||
---|---|---|---|
Line 1: | Line 1: | ||
- | ~~NOTOC~~ | + | ====== Module Waefer Creation 3D ====== |
- | ===== Module Waefer Creation 3D ===== | + | {{: |
---- | ---- | ||
+ | <WRAP group> | ||
+ | <WRAP threequarters column> | ||
+ | ^ Program version | ||
+ | | Availablility | ||
+ | </ | ||
+ | <WRAP quarter column> | ||
+ | <wrap lo> | ||
+ | {{: | ||
+ | {{: | ||
+ | </ | ||
+ | </ | ||
+ | </ | ||
+ | \\ | ||
Module Waefer Creation can be used to design surgical splints to be used during orthognathic surgery. The jaw relation can be adjusted manually using 3D virtual models or taken over from separate Waefer findings exported from module Sim 3D as a result of the treatment planning process.\\ | Module Waefer Creation can be used to design surgical splints to be used during orthognathic surgery. The jaw relation can be adjusted manually using 3D virtual models or taken over from separate Waefer findings exported from module Sim 3D as a result of the treatment planning process.\\ | ||
- | To fix the splint during surgery, drill holes perpendicularly to the occlusal plane. Also labeling the waefer on its surface is possible to ensure the correct patient and splint sequense.\\ | + | To fix the splint during surgery, drill holes perpendicularly to the occlusal plane. Also labeling the waefer on its surface is possible to ensure the correct patient and splint sequense. To support easy and proper insertion, several block out options can be applied.\\ |
- | To support easy and proper insertion, several block out options can be applied. | + | According to the intended purpose, clinical decisions cannot be motivated exclusively or even mainly on evaluation results provided by the software. The classification as a medical device cannot be transferred to treatment measures or the manufacture of orthodontic appliances, even if these take into account the calculation results of the software.\\ |
- | ==== First Steps ==== | + | ===== First Steps ===== |
- Define three points for the waefer plane on each the upper and lower jaw | - Define three points for the waefer plane on each the upper and lower jaw | ||
- Define 2D outline for upper and lower surface with left click in sketch on the right | - Define 2D outline for upper and lower surface with left click in sketch on the right | ||
Line 16: | Line 28: | ||
---- | ---- | ||
- | ==== Module user interface ==== | + | ===== Module user interface |
- | {{:modul_waefer.png? | + | {{:modul_waefer1.png? |
---- | ---- | ||
- | ==== References | + | ===== Links ===== |
- | + | |{{:movie.png? | |
- | Complete workflow: https:// | + |
en/waefer_creation_3d.txt · Last modified: 2024/03/02 15:29 by onyxadmin